CONTENTS

2.4FUNCTION DESCRIPTIONS

2.4.2Notes on function descriptions

These operating instructions only describe those functions that are necessary for operating an ALS 20x that has been configured and set up. These functions are highlighted in grey in the function overview.

Only qualified service technicians may change the settings of the other functions. These

functions are described in the service manual.

The settings range or the individual settings for a function are shown in square brackets.

The default value is italicised for functions that have individual settings.

Settings that consist of several words are shown in quotation marks.

2.4.3LABEL SETUP menu

Load prod. profil function:

Loads product profiles from the internal database.

Product profiles contain product-specific settings.

You can select a maximum of 16 product profiles.

You can only select product profile numbers that have profiles already stored for them.

Dispense speed function:

The speed at which the label is dispensed

Setting range:

ALS 204: [0.0…40.0] m/min; default: 10.0

ALS 206: [0.0…30.0] m/min; default: 10.0

ALS 256: [0.0…50.0] m/min; default: 10.0

Slew speed function:

Feed speed during initialisation

Setting range:

ALS 204: [0.0…40.0] m/min; default: 1.0

ALS 206: [0.0…30.0] m/min; default: 1.0

ALS 256: [0.0…50.0] m/min; default: 1.0

Label pitch function:

Label pitch = label length+space

Setting range: [5.0…600.0] mm

Lab. stop offset function:

Stop position of the label on the dispensing plate

Setting range: [0.0…999.9] mm; default: 20.0

ALS 20x 256

GB

Start offset function:

Distance between the product sensor and the top of the dispensing plate

Setting range: [15.0…999.9] mm; default: 15.0

Product length function:

– Setting range: [0.0…1999.9] mm; default: 0.0

Miss. label tol. function:

Missing label tolerance

The maximum permissible number of successive missing labels on the label strip

Setting range: [0…10] mm; default: 1

Stop count. mode function:

Settings: [enabled, disabled]

Enabled: Dispenser counter counts backwards, starting with the value that has been set using the

MACHINE SETUP > Dispense counter function. When the counter reaches zero, no further labels are dispensed.

Disabled: The dispenser counter counts forwards, which means that the dispenser counter is incremented with each label that is dispensed.

2.4.4MACHINE SETUP menu

Start error stop function:

Determines how the machine responds in the event of a product start error. A product start error occurs when a new start signal arrives before the current dispensing cycle has ended.

Settings: [On, Off]

On: Start errors are issued. If a start error occurs, the device stops and displays a relevant error message.

Off: Start errors are ignored.

Turn-on mode function:

The operating mode of the unit after it is turned on.

Settings: [Online, Offline]

Online: Dispensing mode

Offline: Configuration mode

Language function:

Language of the displayed text

Settings: [English, French, German, Spanish, Italian, Dutch, Danish]

27

Page 31
Image 31
Avery 206, 204, 256 manual Label Setup menu, Machine Setup menu