2.3OPERATING MODES

Online settings

The machine is in dispensing mode.

To switch to the online settings mode:

Press the button.

The display shows the dispensing speed [21A] and the start offset [21C].

The button assignments are as shown on the buttons.

You can increase (‘+’ button) or lower (‘–’ button) both settings in the dispensing mode

[21D].

Dispensing speed:

Setting range:

ALS 204: [2.0…40.0] m/min

ALS 206: [2.0…30.0] m/min

Display fix: The dispensing speed is constant.

Display var: The dispensing speed automatically adjusts to the speed of the conveyor belt (‘speed adaption’).

Start offset:

Setting range: [0.0…999.9] mm

The start offset indicates the distance between the product sensor and the dispensing edge.

Dispensing manually

To manually trigger the dispensing of individual labels:

Press the button.

Dispensing speed: As specified in the setting (see above).

To switch back to dispensing mode:

Press the buttons + .

ALS 20x 256

GB

A

B

 

C

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

 

Offset

 

 

 

12.2 fix

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– +

– +

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E F G H

[21]Control panel in the online settings mode

A Dispensing speed display (here: 12.2 m/min constant) B Dispense label button

C Start offset display (here: 0 mm)

D Explanation of buttons in online settings mode E Button to lower dispensing speed

F Button to increase dispensing speed G Button to lower start offset

H Button to increase start offset