3. Operation

Menu Structure

Please note:

When selecting the baud rate for either RS-232 or RS-485, the user has these choices: 1200, 2400, 9600, 38400, 57600.

When selecting the byte format, the user has these choices:

~N81, (one start bit, eight data bits, one stop bit and no parity bit)

~E71, (one start bit, seven data bits, one stop bit, even parity)

~O71, (one start bit, seven data bits, one stop bit, odd parity.)

Hardware handshaking can be set to ON or OFF.

opJQUR=pÉííáåÖë=jÉåì

From the System Menu, select RS-485 Settings to display the RS-485 Settings Menu.

 

 

 

 

 

RS-485 Settings

 

 

 

> Baud Rate

[57600]

 

 

Handshaking

[OFF]

 

 

Node Number

17

 

 

 

 

 

Figure 3-9.MatrixPRO RS-485 Settings Menu

This menu allows the adjustment of the node number in the conventional manner. The node number can range from 1 to 32. After a factory reset or an RS-232 menu reset, the default node number is set to 17.

fm=^ÇÇêÉëë

From the System Menu, select IP Address to display the IP Address Menu.

IP Address

192.168.000.242

^

Figure 3-10.MatrixPRO IP Address Menu

When this menu item is selected, the cursor (^) will be positioned under the right-most digit in the address. Note that the default IP address is 192.168.000.242.

„To adjust the IP address:

1.The value of the number can be modified upward by rotating the selector knob clockwise (CW).

2.Press SEL to update the number and advance the cursor one place to the left.

3.Repeated presses of the SEL key will advance the cursor through the numeric fields, skipping the decimal-point field delimiter.

22

 

MatrixPRO • 16x16 and 8x8 HD/SD-SDI Router • User’s Guide

 

Page 32
Image 32
Barco 8x8, HD/SD-SDI, 16x16 manual Off