APPENDIX C : SOFT EDGE MATCHING

Stop position

Highlight STOP POSITION with the control disk and press ENTER.

S O F T E D G E

C O R R E C T I O N

S T A R T

 

T O P

 

S T A R T L E FT R I G H T S TO P

B O T T O M

 

S T O P

 

H T E S T M O D E - O FF

V TE S T MO D E - O FF

Select with

or

t h e n <E N TE R >

 

<E XI T> t o re tu rn

 

 

6 39 h

ENTER displays the normal image super- imposed with the internal generated test signal.

EXIT returns to the Random Access Ad- justment Mode main menu.

ADJUST returns to the Operational mode.

APPENDIX C :

Adjust the last right line of the generated test image to deter- mine the image border. This im- age border is the end position of the right soft edge area.

Note : when the stop position is not visible by the first image dis- play, push the control disk until the line becomes visible. Adjust then until the stop position is cor- rect.

Right(width)

Stop position

4 1 5 b

SOFT EDGE MATCHING

ENTER displays the Soft Edge menu.

C-6

 

R5975238 BARCOVISION 701 MULTIMEDIA 070497

 

Page 146
Image 146