Fault Isolation Procedures

Electrical Pretest

Step A

Procedure

Condition

Action

 

 

 

 

1.Key off.

2.Inspect starter/battery connections for integrity.

3. Measure voltage across

 

If voltage is 11 to 13 volts

battery.

 

on a 12 volt system or 22 to

 

 

 

26 on a 24 volt system

 

 

If voltage is outside of

 

 

range

Go to Step B.

Repair or replace batteries and charging system as required. Repeat this step.

 

VOLT

 

V

COM

A

Electrical Pretest

2-2

Page 13
Image 13
BENDIX BW2849 manual Step a, Electrical Pretest