Fault Isolation Procedures

Power-Up Sequence Test, continued

Step C

Procedure

Condition

Action

 

 

 

 

1.Key off.

2.Disconnect Central Processing Unit 32-way connector.

3.Measure resistance between:

• Central Processing Unit 32-way connector pin D3 and Driver Display 4-way connector pin D.

Central Processing Unit 32-way connector pin D3 and ground.

If resistance between D3 and pin D is 0 to .3 ohms and if resistance between pin D3 and ground is more than 10K ohms or open circuit [OL]

If any of the above conditions are not met

Go to Step D.

Repair OEM wiring harness between Driver Display Unit and Central Processing Unit. Go to Step V.