BENDIX BW2849 manual Step E, Clearing on page 1 If code 24 appears

Models: BW2849

1 114
Download 114 pages 4.32 Kb
Page 77
Image 77

Fault Isolation Procedures

Code 24 (SID 6, FMI 2) Speed Input Error, continued

Step E

 

Procedure

 

Condition

 

Action

 

 

 

 

 

 

 

1.

Measure resistance

 

If resistance is more than

 

Repair the OEM wiring harness.

 

 

between speed sensor A

 

10K ohms or open circuit

 

Go to Step V.

 

 

 

 

 

 

and ground.

 

[OL]

 

 

If resistance is less than 10K ohms

 

 

OHMS

 

A

B

 

 

 

V

COM

A

Replace speed sensor. Go to Step V.

 

 

GROUND

 

 

 

 

 

Step V

Procedure

Condition

Action

 

 

 

 

1.Key off.

2.Reconnect all connectors.

3.Key on.

4.Clear Codes. See “Fault Code Retrieval and Clearing” on page 1 - 2.

5.Use Driving Techniques to attempt to reset the code. See “Driving Techniques” on page 1 - 4.

6. Check for Codes. See

 

If no codes

 

Test complete.

“Fault Code Retrieval and

 

 

 

 

 

 

 

 

Clearing” on page 1 - 2.

 

 

 

 

 

 

If code 24 appears

 

Return to Step A to find error in

 

 

 

 

testing.

 

 

 

 

 

 

If code other than 24 appears

 

See “Fault Code Isolation

 

 

 

 

Procedure Index” on page 1 - 3.

(SID 6, FMI

Code 24

2)

 

 

 

2-66

Page 77
Image 77
BENDIX BW2849 manual Step E, Clearing on page 1 If code 24 appears