BENDIX BW2849 Code 24 SID 6, FMI 2 Speed Input Error, If vehicle uses J-1939 or 1587 configuration

Models: BW2849

1 114
Download 114 pages 4.32 Kb
Page 75
Image 75

Fault Isolation Procedures

Code 24 (SID 6, FMI 2) Speed Input Error

Step A

Procedure

Condition

Action

 

 

 

 

1.Using a PC-based or Hand-held Diagnostic Tool verify vehicle speed configuration.

If configuration is set to Discrete

 

Go to Step B.

If vehicle uses J-1939 or

 

 

 

 

J-1587 configuration

 

Repair OEM wiring harness.

 

 

J-1587 or J-1939 data link

 

 

 

 

may not be connected to the

 

 

BendixVORAD® system.

 

 

Go to Step V.

Step B

 

Procedure

Condition

Action

 

 

 

 

 

 

 

1.

Key off.

 

 

 

2.

Disconnect Central Processing

Note: If 32-way connector does not

 

 

 

Unit 32-way connector.

have pins in C10 and C11,

 

 

 

 

 

recheck vehicle configuration

 

 

 

 

 

for speed source. This test is

 

 

 

 

 

used for discrete installations

 

 

 

 

 

only.

 

3.

Measure resistance

If resistance is 2 to 4K ohms

Go to Step C.

 

 

 

 

 

 

 

 

between Central

 

 

 

 

 

 

 

 

 

 

 

 

Processing Unit pins C10

 

 

 

 

 

and C11.

 

 

 

 

 

 

 

If resistance is outside of range

Go to Step D.

 

 

 

 

 

 

 