Component

Description

 

 

Server 1

This server is a member of VLAN 1 and has presence in only one IP

 

subnet. The associated switch port is only a member of VLAN 1, so

 

tagging is disabled.

 

 

Server 2

This server is a member of VLAN 1 and has presence in only one IP

 

subnet. The associated switch port is only a member of VLAN 1, so

 

tagging is disabled.

 

 

Server 3

This server belongs to VLAN 2, and it is logically in the same IP sub-

 

net as Server 5.

 

The associated switch port has tagging disabled.

 

 

Server 4

A member of VLAN 3, this server can communicate only with other

 

servers via a router.

 

The associated switch port has tagging disabled.

 

 

Server 5

A member of VLAN 1 and VLAN 2, this server can communicate only

 

with Server 1, Server 2, and Server 3.

 

The associated switch port has tagging enabled.

 

 

Enterprise

These switches must have all three VLANs (VLAN 1, 2, 3) configured.

Routing switches

They can communicate with Server 1, Server 2, and Server 5 via

 

VLAN 1.

 

They can communicate with Server 3 and Server 5 via VLAN 2.

 

They can communicate with Server 4 via VLAN 3.

 

Tagging on switch ports is enabled.

 

 

NOTE VLAN tagging is required only on ports that are connected to other switches or on ports that connect to tag-capable end-stations, such as servers with VLAN-tagging adapters.