RackSwitch G8000 Application Guide

When TACACS+ Command Logging is enabled, Blade OS configuration commands are logged on the TACACS+ server. Use the following command to enable TACACS+ Command Logging:

RS G8000 (config)# tacacs-server command-logging

The following examples illustrate the format of Blade OS commands sent to the TACACS+ server:

authorization request, cmd=shell, cmd-arg=interface ip accounting request, cmd=shell, cmd-arg=interface ip authorization request, cmd=shell, cmd-arg=enable accounting request, cmd=shell, cmd-arg=enable

Configuring TACACS+ Authentication

1.Configure the Primary and Secondary TACACS+ servers, and enable TACACS authentication.

RS G8000

(config)# tacacs-server primary-host 10.10.1.1

RS

G8000

(config)#

tacacs-server

secondary-host 10.10.1.2

RS

G8000

(config)#

tacacs-server

enable

2.Configure the TACACS+ secret and second secret.

RS G8000 (config)# tacacs-serverprimary-host 10.10.1.1 key <1-32 character secret>

RS G8000 (config)# tacacs-serversecondary-host 10.10.1.2 key <1-32 character secret>

3.If desired, you may change the default TCP port number used to listen to TACACS+. The well-known port for TACACS+ is 49.

RS G8000 (config)# tacacs-server port <TCP port number>

4.Configure the number of retry attempts, and the timeout period.

RS G8000 (config)# tacacs-server retransmit 3

RS G8000 (config)# tacacs-server timeout 5