14 en InstallationPLENA matrix

5.2

Call Station

 

1.

A call station is used as a desktop device. As such be careful do not place this product

 

 

where it is likely to have liquid spilt on it.

 

2.

Take care to when installing not to exceed the cable manufactures’ “bend radius”

 

 

specifications.

 

3.

Be sure that cabling is installed in a way that the cabling will not be damaged, and it will

 

 

not become a hazard.

 

4.

Check that RJ45 connectors have strong locking tabs, and are not able to be

 

 

inadvertently pulled out once installed. Refer to Call Station, page 18.

Notice!

The maximum number of call station IDs that can be configured for each DSP matrix mixer is 8 call stations.

The maximum safe cable distance from the DSP matrix mixer to the last call station on is 500m. This may be extended with the use of better cable and less call stations on that cable run.

If the cables are exposed; use black CAT5 cables. This makes for a better visual look once installed, as it matched the black of the call station.