42 en TroubleshootingPLENA matrix
Problem | Possible cause | Possible solution | |
|
|
|
|
Amplifier: Fault light lit for | – This is indicating | – | The amplifier |
approx. one second. | protection on that |
| automatically retries the |
| channel (overload or |
| channel after this time (1 |
| short condition). |
| min). |
|
| – Note that the amplifier | |
|
|
| will not detect a short- |
|
|
| circuit directly without |
|
|
| signal - for instance, if a |
|
|
| short is on the output, |
|
|
| but no signal is being |
|
|
| driven, the amplifier may |
|
|
| not actually be in fault |
|
|
| mode. As soon as |
|
|
| enough signal is present |
|
|
| to activate the current |
|
|
| protection the fault LED |
|
|
| will light. |
|
|
| |
Amplifier: Fault LED flashes | – This indicates a thermal | – The channel will be | |
quickly for around 30 | error on the channel. |
| re‑activated after it has |
seconds. |
|
| cooled down. |
|
|
|
|
Amplifier: Fault LEDs flash | – This indicates that the | – | Send immediately for |
slowly. | PSU has failed (or |
| service and/or contact |
| thermally cut‑out). |
| the Bosch authorized |
|
|
| dealer or installer for |
|
|
| assistance. |
|
|
| |
Call stations / Wall Control | – RS485 ID cannot be | – Check that the switches | |
Panel's LED keep rotating. | identified. |
| have been full switched |
|
|
| to the appropriate |
|
|
| positions, and reset |
|
|
| power to the unit. |
|
| – Check that the CAT‑5 | |
|
|
| cable is not damaged in |
|
|
| anyway. |
|
| – | Download and connect |
|
|
| with the latest version of |
|
|
| PC GUI and check the |
|
|
| RS485 status "Device > |
|
|
| RS486 device status". |
|
|
|
|
Operation manual | Bosch Security Systems B.V. |