EN 128

Installation and Operating Manual VIP X2

 

 

Pin assignment

The pin assignment for the serial interface depends on the interface mode that is used (see page 84):

Contact

RS232 function

RS422/485 function

IN1

Alarm input 1

Alarm input 1

 

 

 

IN2

Alarm input 2

Alarm input 2

 

 

 

IN3

Alarm input 3

Alarm input 3

 

 

 

IN4

Alarm input 4

Alarm input 4

 

 

 

GND

GND (ground)

GND (ground)

 

 

 

GND

GND (ground)

GND (ground)

 

 

 

R (top)

Relay

Relay

 

 

 

R (bottom)

Relay

Relay

 

 

 

CTS

CTS (clear to send)

RxD- (receive data minus)

 

 

 

RTS

RTS (ready to send)

TxD- (transmit data minus)

 

 

 

RXD

RxD (receive data)

RxD+ (receive data plus)

 

 

 

TXD

TxD (transmit data)

TxD+ (transmit data plus)

 

 

 

+

12 V (power supply)

12 V (power supply)

 

 

 

GND (ground)

GND (ground)

 

 

 

To operate the alarm inputs, connect each alarm input to a ground contact (GND) via a trigger contact.

Appendix