EN 128 | Installation and Operating Manual VIP X2 |
|
|
Pin assignment
The pin assignment for the serial interface depends on the interface mode that is used (see page 84):
Contact | RS232 function | RS422/485 function |
IN1 | Alarm input 1 | Alarm input 1 |
|
|
|
IN2 | Alarm input 2 | Alarm input 2 |
|
|
|
IN3 | Alarm input 3 | Alarm input 3 |
|
|
|
IN4 | Alarm input 4 | Alarm input 4 |
|
|
|
GND | GND (ground) | GND (ground) |
|
|
|
GND | GND (ground) | GND (ground) |
|
|
|
R (top) | Relay | Relay |
|
|
|
R (bottom) | Relay | Relay |
|
|
|
CTS | CTS (clear to send) | RxD- (receive data minus) |
|
|
|
RTS | RTS (ready to send) | TxD- (transmit data minus) |
|
|
|
RXD | RxD (receive data) | RxD+ (receive data plus) |
|
|
|
TXD | TxD (transmit data) | TxD+ (transmit data plus) |
|
|
|
+ | 12 V (power supply) | 12 V (power supply) |
|
|
|
– | GND (ground) | GND (ground) |
|
|
|
To operate the alarm inputs, connect each alarm input to a ground contact (GND) via a trigger contact.
Appendix | Bosch Security Systems |