VIP X2 Installation and Operating Manual | EN 81 |
|
|
Relay
You can configure the switching behavior of the relay output. You can specify an open switch relay (normally closed contact) or a closed switch relay (normally open contact).
You can also specify whether the output should operate as a bistable or monostable relay. In bistable mode, the triggered state of the relay is main- tained. In monostable mode, you can set the time after which the relay will return to the idle state.
You can select different events that automatically activate the output. It is possi- ble, for example, to turn on a floodlight by triggering a motion alarm and then turning the light off again when the alarm has stopped.
Idle state:
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is to operate as an NC contact.
Operating mode:
Select an operating mode for the relay.
For example, if you want an