VIP X2 Installation and Operating Manual |
| EN 135 | |
|
|
|
|
Specifications |
|
|
|
Device |
|
|
|
Operating voltage | 12 ... 24 V DC, power supply unit with various pri- | ||
| mary adapters included | ||
Power consumption | Approx. 6 VA | ||
LAN interface | 1 | × Ethernet 10/100 | |
| automatic adjustment, | ||
| half/full duplex, RJ45 | ||
Data interfaces | 1 | × RS232/RS422/RS485, bidirectional, ST500 | |
| 1 | × USB 2.0 | |
Alarm inputs | 4 | × | |
| tact), maximum trip resistance 10 Ohm | ||
Relay output | 1 | × | |
Video inputs | 2 | × BNC jacks | |
| each 0.7 ... 1.2 | ||
Audio input (Line In) | 1 | × 3.5 mm stereo jack socket, | |
| 5.5 | ||
Audio output (Line Out) | 1 × 3.5 mm stereo jack socket, | ||
| 3 | ||
Microphone input | 1 | × | |
| impedance 2 kOhm typ., supply 2.3 V typ. | ||
Speaker output | 1 | × | |
| impedance 4 Ohm min. | ||
Displays | 3 | × LED (operating voltage, network connection, | |
| data transfer) in rear panel | ||
Operating conditions | Temperature: 0 ... +40°C (+32 ... +104°F) | ||
| relative humidity: 20 ... 80%, | ||
| |||
Regulatory approvals | CE: IEC 60950; UL 1950; AS/NZS 3548; | ||
| EN |
EN 55024; EN
FCC 47 CFR Chapter 1 Part 15
Bosch Security Systems | Appendix |