Specifications

 

 

 

Device

 

 

 

Operating voltage

12 ... 24 V DC, power supply unit with various pri-

 

mary adapters included

Power consumption

Approx. 6 VA

LAN interface

1

× Ethernet 10/100 Base-T,

 

automatic adjustment,

 

half/full duplex, RJ45

Data interfaces

1

× RS232/RS422/RS485, bidirectional, ST500

 

1

× USB 2.0

Alarm inputs

4

× push-in terminals (non-isolated closing con-

 

tact), maximum trip resistance 10 Ohm

Relay output

1

× push-in terminal, 30 Vp-p, 2 A

Video inputs

2

× BNC jacks

 

each 0.7 ... 1.2 Vp-p, 75 Ohm, PAL/NTSC

Audio input (Line In)

1

× 3.5 mm stereo jack socket,

 

5.5 Vp-pmax., impedance 9 kOhm typ.

Audio output (Line Out)

1 × 3.5 mm stereo jack socket,

 

3

Vp-pmax., impedance 16 Ohm min.

Microphone input

1

× push-in terminal, 2.8 Vp-pmax. at –20 dB,

 

impedance 2 kOhm typ., supply 2.3 V typ.

Speaker output

1

× push-in terminal, 6 Vp-pmax., 1 W rms,

 

impedance 4 Ohm min.

Displays

3

× LED (operating voltage, network connection,

 

data transfer) in rear panel

Operating conditions

Temperature: 0 ... +40°C (+32 ... +104°F)

 

relative humidity: 20 ... 80%,

 

non-precipitating

Regulatory approvals

CE: IEC 60950; UL 1950; AS/NZS 3548;

 

EN 55103-1, -2; EN 55130-4; EN 55022;

EN 55024; EN 61000-3-2; EN 61000-3-3;

FCC 47 CFR Chapter 1 Part 15

Bosch Security Systems 2006-12 V2.5