VIP X2 Installation and Operating Manual | EN 69 |
|
|
Alarm sources
You can configure the possible alarm triggers for the VIP X2 (for example, the alarm inputs).
Alarm input 1: to Alarm input 4:
Select the option On to activate the alarm by the corresponding external alarm sensor. Otherwise, select Off.
Select Active high if the alarm is to be triggered by closing the contact. Select Active low if the alarm is to be triggered by opening the contact.
Name:
You can enter a name for each alarm input, which is then displayed below the icon for the alarm input on the LIVEPAGE if configured correctly (see Livepage configuration, page 94).
Video loss alarm:
Activate the checkbox if you want an interruption of the video signal to also trigger an alarm. A selected video input is indicated by a check mark.
Note
The numbering follows the labeling of the video inputs on the actual unit.
Bosch Security Systems | Configuration using a Web browser |