VIP X2 Installation and Operating Manual

EN 71

 

 

Destination IP address:

For each number enter the corresponding IP address for the desired remote sta- tion.

Destination password:

If the remote station is password protected, enter the password here.

You can save up to ten target IP-addresses on this page. This means that also only ten passwords for connections can be defined here. If more than ten connections are necessary, for example when connections are initiated by a controlling system, such as VIDOS or Bosch Video Management System, you can define a general password. The VIP X2 can make connections with this general password to all devices protected by that same password. In such cases, proceed as follows:

Select 10 in the Number of destination IP address list box.

Enter 0.0.0.0 in the Destination IP address field.

Enter the password in the Destination password field.

Set the user password of all the devices to be connected to this password.

Note

Setting target 10 to the destination IP address 0.0.0.0 will override its function as the tenth address to try for auto-connect on alarm. Instead the parameter is used only to store the general password.

Remote port:

Choose the browser-port, depending on the network configuration. Port 443 for HTTPS connections is only available if the On option in SSL encryption is active.

Bosch Security Systems 2006-12 V2.5

Configuration using a Web browser