EN 82 | Installation and Operating Manual VIP X2 |
|
|
Relay follows:
If required, select a specific event that will trigger the relay. The following events are possible triggers:
❚Off
Relay is not triggered by events
❚Connection
Trigger whenever a connection is made
❚Video alarm 1
Trigger by interrupting the video signal
Note
The relay is only triggered by an interruption in the video signal at input Video In 1, and not by interruptions in the other video signal.
❚Motion alarm 1
Trigger by means of motion alarm as configured on the page VCA for Video 1 (see page 73)
❚Local input 1
Trigger by external alarm input 1
❚Remote input 1
Trigger by remote station's switching contact (only if a connection exists)
Relay name:
You can assign a name for the relay here. The name is shown on the button next to Trigger relay. The Livepage can also be configured to display the name under the relay icon.
Trigger relay:
Click the button to trigger the relay manually (for testing or to operate a door opener, for example).