Setting Parity: Press the (+) or (–) key to display other choices.

 

 

Default: Even

 

 

Selections: Even, odd, none

 

PARITY

The parity of the printer must match the parity of the host

 

 

computer for accurate communications to take place. Select the

 

 

parity that matches the one being used by the host computer.

 

 

 

 

 

Setting Stop Bits: Press the (+) or (–) key to display other

 

 

choices.

 

 

Default: 1 stop bit

 

STOP BITS

Selections: 1 stop bit, 2 stop bits

 

 

The stop bits of the printer must match the stop bits of the host

 

 

computer for accurate communications to take place. Select the

 

 

stop bits that match the one being used by the host computer.

 

 

 

 

 

Setting Host Handshake: Press the (+) or (–) key to display

 

 

other choices.

 

 

Default: XON/XOFF

 

HOST HANDSHAKE

Selections: XON/XOFF, DTR/DSR

 

 

The handshake protocol of the printer must match the handshake

 

 

protocol of the host computer for communications to take place.

 

 

Select the handshake protocol that matches the one being used

 

 

by the host computer.

 

 

 

 

 

Setting Protocol: Press the (+) or (–) key to display other

 

 

choices.

 

 

Default: None

 

 

Selections: None, Zebra, ACK/NACK

 

 

Protocol is a type of error checking system. Depending on the

 

 

selection, an indicator may be sent from the printer to the host

 

PROTOCOL

computer signifying that data has been received. Select the

 

 

protocol that is requested by the host computer. For more details,

 

 

contact Technical Support.

 

 

NOTE: “Zebra” is the same as ACK/NACK except that with

 

 

“Zebra” the response messages are sequenced.

 

 

NOTE: If “Zebra” is selected, printer must use “DTR/DSR” host

 

 

handshake protocol.

 

 

 