3RVLWLRQLQJ￿WKH￿0HGLD￿6HQVRUV

The correct positioning of the media sensors is important — it can make the difference between a perfect label and a call to Technical Support!

7UDQVPLVVLYH￿6HQVRU

The web or gap sensor (transmissive sensor) detects the gap between labels.

The transmissive sensor actually consists of two sections: a light source (the lower media sensor) and a light sensor (the upper media sensor). The media passes between the two.

The upper media sensor must be positioned:

Directly over the hole or notch, or

Anywhere along the width of the media if there is a gap between labels.

NOTE: If you are using continuous media, position the upper media sensor over the media so that the printer can detect an out-of-paper condition.

10

Bradyprinter 200M-e and 200M-e 300 User’s Guide