$￿ODEHO￿IRUPDW￿ZDV￿VHQW￿WR￿WKH￿SULQWHU￿￿￿6HYHUDO￿ODEHOV￿SULQW￿￿WKHQ￿ WKH￿SULQWHU￿VNLSV￿￿PLVSODFHV￿￿PLVVHV￿￿RU￿GLVWRUWV￿WKH￿LPDJH￿RQ￿WKH￿

ODEHO￿

Problem

Solution

The host is set to EPP parallel

Change the settings on the computer host to standard

communications.

parallel communications.

 

 

 

Ensure that the flow control settings match.

 

 

The serial communication settings are

Check the communication cable length. See page 22 for

requirements.

incorrect.

 

Check the printer driver or software communications

 

 

settings (if applicable).

 

 

$￿ODEHO￿IRUPDW￿ZDV￿VHQW￿WR￿WKH￿SULQWHU￿EXW￿QRW￿UHFRJQL]HG￿￿￿7KH￿ '$7$￿OLJKW￿IODVKHV￿EXW￿QR￿SULQWLQJ￿RFFXUV￿

Problem

Solution

The prefix and delimiter characters set in the

Verify the prefix and delimiter characters. See page 55.

printer do not match the ones in the label

 

format.

 

 

 

 

Ensure that ZPL is being used.

Incorrect data is being sent to the printer.

 

Check the communication settings on the computer.

 

Ensure that they match the printer settings.

 

 

7KH￿SULQWHU￿IDLOV￿WR￿FDOLEUDWH￿RU￿GHWHFW￿WKH￿WRS￿RI￿WKH￿ODEHO￿

Problem

Solution

The printer was not calibrated for the label

Perform the calibration procedure on page 17.

being used.

 

 

 

The printer is configured for continuous

Set the media type to non-continuous media.

media.

 

 

 

The driver or software configuration is not set

As driver or software settings produce ZPL commands that

correctly.

can overwrite the printer configuration, check the driver or

 

software media-related setting.

 

 

76