Configuration and Calibration |
Bank 1 (For
The
Bank 1 switches must be properly positioned to establish serial data communications with the host computer. Thereafter, the position of these switches should not be changed.
Note:
If these switches are in the proper position to match the communication configuration of the host computer, and the printer is not receiving data, refer to the Interconnections Section and make sure the correct interface cable is being used.
Note: The printer is fixed at 1 stop bit, so make sure that your host device is also set at 1 stop bit.
Bank 1
| Switch | Baud Rate |
|
| 3 2 1 |
| |
|
|
| |
| R R R | 9600 baud |
|
|
|
|
|
| R R L | 19200 baud |
|
|
|
|
|
| R L R | 110 baud |
|
|
|
|
|
| R L L | 300 baud |
|
|
|
|
|
| L R R | 600 baud |
|
|
|
|
|
| L R L | 1200 baud |
|
| L L R | 2400 baud |
|
|
|
|
|
| L L L | 4800 baud |
|
| Switch | Data Bits |
|
| (Must be set to 8 Data Bits |
| |
| 4 |
| |
| to use Code Page 850.) |
| |
|
|
| |
| R | 7 Data bits |
|
|
|
|
|
| L | 8 Data bits |
|
| Switch | Parity |
|
| (If you choose 7 data bits, you must |
| |
| 6 5 |
| |
| choose either even or odd parity.) |
| |
|
|
| |
| R R | Even parity |
|
| R L | Parity disabled |
|
| L R | Odd parity |
|
| L L | Parity disabled |
|
| Switch | Communication |
|
| 7 | Handshake Control |
|
| R | XON/XOFF control |
|
|
|
|
|
| L | DTR/DSR control |
|
| Switch | Error Detection Protocol |
|
| 8 |
| |
|
|
| |
| R | No error detection |
|
| L | Error detection active |
|
|
|
|
|
Table 4.1