Preventive Maintenance

Overview

This section contains Preventive Maintenance information for the Brady M-Series Printer. These procedures may be performed by the operator.

Cleaning

Exterior Surfaces

The exterior surfaces of the printer may be cleaned as required by using a lint free cloth. Do not use harsh or abrasive cleaning agents or solvents. If necessary, a mild detergent solution or desktop cleaner may be used sparingly.

Interior

Remove any accumulated dirt/lint from the interior of the printer using a soft bristle brush and/or vacuum cleaner. This area should be inspected after every four rolls of media.

The cleaning supplies are found in the Printer Cleaning Kit (PCK-2).

AREA

METHOD

INTERVAL

 

 

 

Printhead

Alcohol

After every roll of

Platen Roller

Alcohol

media (or 500 ft. of

Upper and Lower

Air Blow

fanfold media) when

Media Sensors

 

printing direct thermal

Media Path

Alcohol

or after every roll of

Ribbon Sensor

Air Blow

ribbon when printing in

 

 

thermal transfer mode.

 

 

 

Peel/Tear Bar

Alcohol

As needed.

Label Available Sensor

Air Blow

Monthly.

Table 6.1 Cleaning Schedule

6-1