Adjustments |
Upper Transmissive Media Sensor Position Adjustment
To adjust the upper media sensor to accommodate
1.Remove the ribbon and locate the Upper Media Sensor.
2.Loosen the Phillips head screw.
3.Slide the upper sensor along the slot to the desired position. When using media that has a web between labels, position the media sensor anywhere along the web (except if you have labels with rounded corners, do not position the sensor where the rounded corners of the label might be detected). When using tag stock, position the upper sensor directly over the hole or notch.
4.Tighten the Phillips head screw.
260M only: To adjust the upper section of the Transmissive Media Sensor for the outside half of the media width, call a service technician.