M-Series User ’s Guide

Configuration and Calibration

the printer. If non-continuous media is sensed, Label Length is also calibrated. If ribbon is sensed, the Thermal Transfer Print Method is configured. If no ribbon is present, the Direct Thermal Print Method is configured.

The results of this calibration are stored in the printer’s memory. These parameters will remain in effect until the next calibration is performed. The Printer Configuration Printout, which prints when the CANCEL Key Self Test is performed, lists these results as well as other printer parameters.

Note: If the printer is in the Peel-Off Mode, the operator must

catch” the labels as they are peeled away from the backing during this procedure.

1.Load media and ribbon (if used). Make sure the Media Sensor is properly positioned (see Chapter 7 “ Adjustments” ).

IMPORTANT: To use a 260M in Black-Mark Sensing Mode, make sure you set the Bank 2 DIP switches appropriately (see page 4-3).

2.Turn the power switch ON. When the Power ON Self Test is complete, the POWER, PAUSE, and PAPER/RIBBON lights will be ON.

3.Press the MODE key 3 times briefly. PAUSE and CALI- BRATE lights turn ON.

4.Press UP (FEED Key) to calibrate. The printer feeds some me- dia. The MODE lights will flash ON and OFF to indicate that the settings have been saved in memory.

5.Press PAUSE to exit PAUSE mode. PAUSE light turns OFF.

4-5