OPERATION
Air Compressor Operating Location
Place generator in a well ventilated area, which will allow for removal of deadly exhaust gas. DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area (Figure 4). Prevailing winds and air currents should be taken into consideration when positioning generator.
The Air Compressor Pump is designed to allow for proper cooling.Ventilation openings on compressor are necessary to maintain proper operating temperature. DO NOT place rags or containers on or near these openings. Keep Air Filter clear of obstructions that could reduce airflow to air compressor.
WARNING
Fuel and its vapors are extremely flammable and explosive.
Fire or explosion can cause severe burns or death.
WHEN OPERATING EQUIPMENT
•This air compressor is not for use in mobile equipment or marine applications.
•DO NOT tip engine or equipment at angle which causes fuel to spill.
•Secure air compressor in a level, stable position.
WARNING
Running air compressor gives off carbon monoxide, an odorless, colorless, poison gas.
Breathing carbon monoxide can cause nausea, fainting or death.
•Operate air compressor ONLY outdoors.
•Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.
•DO NOT operate air compressor inside any building, confined area or enclosure, such as basements, garages or a similar location, even if doors or windows are open.
DO NOT place air compressor where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure that exhaust is kept away from any windows, doors, ventilation intakes or other openings that
OPERATION
can allow exhaust to collect in a confined area Prevailing winds and air currents should be taken into consideration when positioning air compressor (see Figure 4).
Figure 4 — Air Compressor Location
Exhaust Port
Typical Unit Shown
If you have any problems with the operation of your air compressor, call the air compressor helpline at
Break-In Procedure
Before first use of this equipment, the system must undergo a
CAUTION
Serious damage may result if the described
•This procedure is required before air compressor is put into service and when Check Valve or a complete Air Compressor Pump has been replaced.
1.Make sure engine ON/OFF switch is in OFF position (see Figure 5).
Figure 5 - ON/OFF Switch
On/Off switch shown in OFF position
9