3.6Fixing Unit

(1)Remove the two M4x16 tapping screws.

(2)Lifting the fixing unit, disconnect the thermistor connector on the EL PCB first, then the two heater harnesses.

Taptite, cup M4x16

Fixing Unit

Taptite, cup M4x16

EL PCB

Thermistor harness

Heater harness (Brown)

Thermistor connector

Heater harness

(Blue)

 

Fig. 3-7

Note:

The eject sensor actuator may also be removed when removing the fixing unit. In this case be sure to re-assemble the eject sensor actuator when re-assembling the fixing unit.

(3)Remove the two M3x12 tapping screws.

(4)Open the fixing unit cover along the open side of the fixing unit cover.