Brother HL-1020, HL-820, HL-1040 manual Low-voltage Power Supply PCB Assy

Models: HL-1040 HL-820 HL-1020

1 305
Download 305 pages 16.03 Kb
Page 61
Image 61

(3)Disconnect the eight connectors from the PCB. (Three connectors have already been disconnected when removing the scanner unit.)

Panel Sensor

 

 

 

PCB ASSY

1

 

 

 

2

 

 

 

3

5

 

10

4

 

 

 

6

 

9

 

 

 

8

 

 

 

 

 

(Name of the Harnesses)

7

 

1.

Low-voltage harness

 

 

2. Erase lamp harness

 

 

3.

Toner harness

 

 

4. Scan motor flat cable

 

 

5.

Laser harness

 

 

6.

Solenoid harness

 

 

7. Main / sub motor connector

 

 

8. Fan motor 1 harness

 

 

9. Fan motor 2 harness

Main frame

 

10. High-voltage flat cable

 

 

 

 

 

Fig. 3-19

 

Note:

When re-assembling, the cable connectors must be inserted securely into the PCB

￿connectors and the PCB must not be stressed by the harnesses.

The connectors should be inserted by matching the housing color and the number of pins.

3.11Low-voltage Power Supply PCB ASSY

(1)Remove the one M4x12 tapping screw securing the low-voltage power supply PCB ASSY.

(2)Disconnect the two connectors for the heater harness and the LV harness from the PCB.

Low-voltage Power Supply ASSY

H r h rn

LV harness

Fig. 3-20

III-12