(3)Disconnect the eight connectors from the PCB. (Three connectors have already been disconnected when removing the scanner unit.)

Panel Sensor

 

 

 

PCB ASSY

1

 

 

 

2

 

 

 

3

5

 

10

4

 

 

 

6

 

9

 

 

 

8

 

 

 

 

 

(Name of the Harnesses)

7

 

1.

Low-voltage harness

 

 

2. Erase lamp harness

 

 

3.

Toner harness

 

 

4. Scan motor flat cable

 

 

5.

Laser harness

 

 

6.

Solenoid harness

 

 

7. Main / sub motor connector

 

 

8. Fan motor 1 harness

 

 

9. Fan motor 2 harness

Main frame

 

10. High-voltage flat cable

 

 

 

 

 

Fig. 3-19

 

Note:

When re-assembling, the cable connectors must be inserted securely into the PCB

￿connectors and the PCB must not be stressed by the harnesses.

The connectors should be inserted by matching the housing color and the number of pins.

3.11Low-voltage Power Supply PCB ASSY

(1)Remove the one M4x12 tapping screw securing the low-voltage power supply PCB ASSY.

(2)Disconnect the two connectors for the heater harness and the LV harness from the PCB.

Low-voltage Power Supply ASSY

H r h rn

LV harness

Fig. 3-20