10. Adjustment
10-18. Checking the input sensor and DIP switch input
P
POWER q
e
R E S E T
w
T E S T
PROGRAM NO.
SPEED
COUNTER
P1 P2
P3 P4
r
BOBBIN.WIND | S E L E C T |
t
1.When the
·When sensor is ON | ·When sensor is OFF | ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2.Each time the SELECT switch t is pressed, a different indicator will illuminate and the operating condition for the corresponding item will appear on the display window r
·When
·When COUNTER indicator is illuminated ..... Presser sensor (ON when presser is lowered)
*1 The synchronizer display simultaneously displays the needle up signal (3rd digit), the
[ H L L] | “H” when the sensor is on, and “L” when the sensor is off | |||
|
|
|
| Needle down signal |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| Needle up signal |
|
|
|
|
If the DIP switches at the side of the operation panel are changed at this time, the number of the DIP switch which was changed will be displayed in the 4th digit position of the display window r for about one second.
NOTE:
The DIP switch can be changed at this time without turning off the power so that you can check the DIP switch input. However, you should normally always turn off the power when changing DIP switch settings.
3. Press the TEST switch w again to return the display to the normal condition.
53