![16. Table of error codes](/images/new-backgrounds/176658/176658143x1.webp)
16. Table of error codes
16. Table of error codes
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before opening the face plate of the control box. Touching areas where high voltages are present can result in severe injury.
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display window. Follow the remedy procedure to eliminate the cause of the problem.
Code | Cause | Remedy | |
|
|
| |
Machine specification select connector is not | Turn off the power and check if connectors P3 is | ||
connected properly. | disconnected. | ||
| |||
|
|
| |
|
| Turn off the power, and then turn the machine pulley to | |
Problem with machine motor stopping, or | check if the machine has locked up. Check the | ||
synchronizer connection error. | synchronizer connection. Check if connectors P11, P12 | ||
| |||
|
| and P13 are disconnected. | |
Machine motor operation error. | Turn off the power and check the ground wire | ||
connection. | |||
|
| ||
|
|
| |
Data is outside possible sewing area due to | Press the RESET switch, and then set the enlargement | ||
enlargement ratio setting. | ratio again. | ||
| |||
Stitch pattern data overlaps the sewing area | Press the RESET switch, and then reset the memory | ||
when area limiting is active. | switches “30” and “31” or enlargement ratio. | ||
| |||
|
|
| |
| The data format of the user program (% or | After changing the setting of DIP switch | |
mm) does not match the setting of DIP switch | memory settings. (Refer to | ||
| settings”.) | ||
|
|
| |
Length of a stitch exceeds 10 mm. | Press the RESET switch, and then set the enlargement | ||
ratio again. | |||
|
| ||
Abnormality in the sewing data. | If programming a new sewing data, repeat the | ||
procedure from the beginning. | |||
|
| ||
Invalid program number specified. | Press the RESET switch and specify a correct number. | ||
| |||
|
|
| |
|
| Turn the pulley to align the index mark with the needle | |
Needle bar does not stop when the needle is | up stop position. (Refer to | ||
raised. | up stop position”.) Check the | ||
| |||
|
| ||
|
|
| |
Presser has not been lowered. | Refer to “18. Troubleshooting”. | ||
Presser cannot be raised. | |||
Turn off the power and check the connection of presser | |||
Presser is not raised. | |||
sensor connector P1. | |||
Presser cannot be lowered. | |||
| |||
Cooling fan does not operate. | Turn off the power, and then check if the cooling fan is | ||
blocked with scraps of thread. | |||
|
| ||
|
|
| |
Motor PROM is not correctly inserted. | Turn off the power and check. | ||
Foot switch was depressed when the power | Turn off the power and check. | ||
was turned on. | |||
|
| ||
An operation panel switch was depressed | Turn off the power and check the operation panel. | ||
when the power was turned on. | Check that all panel cords are normal. | ||
| |||
|
|
| |
| Abnormal drop in power supply voltage, or | Turn off the power and check the input voltage. After | |
| turning off the power, wait 3 seconds or more before | ||
power was turned on again immediately after | |||
turning it on again. (Refer to | |||
| it was turned off. | ||
| voltage”.) | ||
|
| ||
Abnormal rise in power supply voltage. | Turn off the power and check the input voltage. (Refer | ||
to | |||
|
| ||
|
|
|
65