14. Changing functions using the DIP switches
14. Changing functions using the DIP switches
14-1. Operation panel DIP switches
The operation panel DIP switches q are used to change functions which might need to be changed depending on the sewing conditions.
NOTE:
Always turn off the power before setting the DIP switches.
The functions shown in the table below can be changed by means of these DIP switches.
* All DIP switches are set to OFF at the time of shipment.
q
Switch | Motion when set to ON | ||
|
|
| |
Presser does not automatically lift after sewing is | See | ||
completed. | |||
| mode” | ||
| |||
|
|
| |
User program mode is available. |
| ||
|
|
| |
– |
| ||
|
|
| |
The presser does not rise automatically when a split is found. | |||
|
|
| |
| Displays the enlargement/reduction ratio in millimeter units instead of as a percentage. | ||
(After changing this setting, be sure to carry out the | |||
| page 38.) |
| |
Enlargement of pattern size is not available. |
| ||
|
|
| |
Program number is fixed. |
| ||
|
|
|
14-2. Setting the presser mode
Through the combination of DIP switches
Pedal specifications | Raising the presser at the sewing end | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Single pedal | Presser is raised automatically. |
|
|
|
|
|
| ||
|
|
|
|
|
| ||
ON |
|
|
| Single pedal | Presser is raised by pressing the pedal. | ||
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| ON | Two pedals | Presser is raised automatically, then it is lowered by | ||
|
|
| pressing the pedal. | ||||
|
|
|
|
|
|
| |
|
|
|
| ||||
ON | ON | Two pedals | Presser is kept lifted while the pedal is pressed. | ||||
|
|
|
|
|
|
|
|
61