h Clean the corona wire inside the drum unit by gently sliding the green tab from left to right and right to left several times.

1

Note

Be sure to return the tab to the home position (a) (1). If you do not, printed pages may have a vertical stripe.

i Put the drum unit and toner cartridge assembly back into the machine.

j Close the front cover of the machine.

Note

After you replace a toner cartridge, DO NOT turn off the machine's power switch or open the front cover until the LCD clears the Please Wait message and returns to Ready mode.

Routine maintenance

Cleaning the corona wire

If you have print quality problems, clean the corona wire as follows:

a Leave the machine turned on for 10 minutes for the internal fan to cool the extremely hot parts inside the machine.

b Press the front cover release button and then open the front cover.

c Take out the drum unit and toner cartridge assembly.

A

69