WSW03 (PABX* mode setting)

Selector

Function

 

 

Setting and Specifications

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNG detection when sharing a

 

 

 

 

 

 

 

1

modular wall socket with a

 

0:

A

 

 

1:

B

 

telephone

 

 

 

 

 

 

 

 

 

No.

2

3

4

 

 

 

 

 

 

0

0

0

:

50 ms

 

 

 

0

0

1

:

210 ms

2

Min. detection time length of

 

0

1

0

:

500 ms

PABX* dial tone, required for

 

0

1

1

:

800 ms

4

starting dialing

 

1

0

0

:

900 ms

 

 

 

1

0

1

:

1.5 sec.

 

 

 

1

1

0

:

2.0 sec.

 

 

 

1

1

1

:

2.5 sec.

 

 

 

 

 

 

 

 

 

 

CNG detection when sharing a

 

 

 

 

 

 

 

5

modular wall socket with a

 

0:

A

 

 

1:

B

 

telephone

 

 

 

 

 

 

 

 

 

No.

6

7

 

 

 

 

 

 

 

0

0

 

: No detection

 

 

 

 

 

 

 

(3.5 sec. WAIT)

6

 

 

0

1

 

: No detection

 

Dial tone detection in PABX*

 

 

 

 

 

(5 sec. WAIT)

7

 

 

1

0

 

: No detection

 

 

 

 

 

 

 

(7 sec. WAIT)

 

 

 

1

1

 

: Detection

 

 

 

 

 

 

 

(Frequency only)

8

“R” key function

0: 1st dial tone

 

 

1: No 1st dial

detection add

 

tone detection

 

 

 

 

 

 

 

 

 

 

 

 

* PABX: Private automatic branch exchange

NOTE: Selectors 2 through 4 and 6 through 8 are not applicable where no PABX is installed.

Selectors 1 and 5: CNG detection when sharing a modular wall socket with a telephone

These selectors determine whether or not the equipment detects a CNG signal when a line is connected to a telephone sharing a modular wall socket with the equipment. Upon detection of CNG signals by the number of cycles specified by these selectors, the equipment interprets CNG as an effective signal and then starts FAX reception.

Selector

Cycle

No. 1

No. 5

 

 

 

 

0 (A)

0 (A)

0.5 cycle

0 (A)

1 (B)

1.0 cycle

1 (B)

0 (A)

1.5 cycles

1 (B)

1 (B)

2.0 cycles

 

 

 

Selectors 2 through 4: Min. detection time length of PABX dial tone, required for starting dialing

Upon detection of the PABX dial tone for the time length set by these selectors, the equipment starts dialing.

These selectors are effective only when both selectors 6 and 7 are set to “1” (Detection).

V - 13

Page 106
Image 106
Brother FAX-931, MFC-970MC, FAX-921 service manual WSW03 PABX* mode setting