WSW10 (Protocol definition 2)

Selector

Function

 

 

Setting and Specifications

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Switching of DPS, following the

 

0: No

 

1: Yes

CML ON/OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Time length from transmission of

 

0: 100 ms

1:

50 ms

the last dial digit to CML ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Time length from CML ON to CNG

 

0:

2 sec.

 

1:

4 sec.

transmission

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time length from CML ON to CED

 

 

 

 

 

 

4

transmission (except for facsimile-

 

0:

0.5 sec.

1:

2 sec.

 

to-telephone switching)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

5

6

 

 

 

5

 

 

0

0

:

1 time

 

No. of training retries

 

0

1

:

2 times

6

 

 

 

1

0

:

3 times

 

 

 

 

 

 

1

1

:

4 times

 

 

 

 

 

 

 

 

7

Not used.

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selector 1: Switching of DPS, following the CML ON/OFF

Setting this selector to "1" automatically switches DPS following the CML ON/OFF operation.

Selector 2: Time length from transmission of the last dial digit to CML ON

This selector sets the time length from when the equipment transmits the last dial digit until the CML relay comes on.

Selector 3: Time length from CML ON to CNG transmission

This selector sets the time length until the equipment transmits a CNG after it turns on the CML relay.

Selector 4: Time length from CML ON to CED transmission

This selector sets the time length until the equipment transmits a CED after it turns on the CML relay. This setting does not apply to switching between facsimile and telephone.

Selectors 5 and 6: No. of training retries

These selectors set the number of training retries to be repeated before automatic fallback.