V - 43
WSW30 (Function setting 8)
Selector
No. Function Setting and Specifications
1
|
3
Detection level of dial tone or
busy tone for the built-in TAD
operation
No. 1 2 3
0 0 0 :-38.0 dBm (A)
0 0 1 :-39.5 dBm (B)
0 1 0 :-41.0 dBm (C)
0 1 1 :-42.5 dBm (D)
1 0 0 :-44.0 dBm (E)
1 0 1 :-45.5 dBm (F)
1 1 0 :-47.0 dBm (G)
1 1 1 :-48.5 dBm (H)
4
|
6Not used.
7
8Recording intensity control
No.7 8
0 0 :A
0 1 :B
1 0 :C
1 1 :D
NOTE: Selectors 1 through 3 are applicable to those models equipped with a built-in TAD.
ll Selectors 1 through 3: Detection level of dial tone or busy tone for built-in TAD operation
If dial tone or busy tone inputted during ICM recording is below the level specified by these
selectors, the TAD stops recording and disconnects the line.
ll Selectors 7 and 8 Recording intensity control