WSW09 (Protocol definition 1)

Selector

Function

 

 

Setting and Specifications

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Frame length selection

 

0:

256 octets

1:

64 octets

 

 

 

 

 

 

 

2

Use of non-standard commands

 

0:

Allowed

1:

Prohibited

 

 

No.

3

4

 

 

 

 

3

 

 

0

0

:

4 times

 

 

No. of retries

 

0

1

:

3 times

 

4

 

 

1

0

:

2 times

 

 

 

 

1

1

:

1 time

 

 

 

 

 

 

 

 

5

T5 timer

 

0:

300 sec.

1:

60 sec.

 

 

 

 

 

 

 

 

6

T1 timer

 

0:

35 sec.

 

1:

40 sec.

 

 

 

 

 

 

 

 

 

 

 

No.

7

8

 

 

 

 

7

Elapsed time for time-out control

 

0

0

:

60 sec.

 

 

for no response from the called

 

0

1

:

140 sec. (in the French versions)

 

station in automatic sending

 

8

 

 

 

 

70 sec. (in other versions)

mode

 

 

 

 

 

1

0

:

90 sec.

 

 

 

 

 

 

 

 

 

 

 

1

1

:

35 sec.

 

 

 

 

 

 

 

 

 

 

NOTE: Selectors 1 through 5 are not applicable in those models which do not support ECM.

Selector 1: Frame length selection

Usually a single frame consists of 256 octets (1 octet = 8 bits). For communications lines with higher bit error rate, however, set selector 1 to "1" so that the facsimile equipment can divide a message into 64-octet frames.

Remarks: The error correction mode (ECM) is a facsimile transmission manner in which the equipment divides a message into frames for transmission so that if any data error occurs on the transmission line, the equipment retransmits only those frames containing the error data.

Selector 2: Use of non-standard commands

If this selector is set to "0," the equipment may use non-standard commands (the machine’s native- mode commands, e.g., NSF, NSC, and NSS) for communications. If it is set to "1," the equipment will use standard commands only.

Selectors 3 and 4: No. of retries

These selectors set the number of retries in each specified modem transmission speed.

Selector 5: T5 timer

This selector sets the time length for the T5 timer.

Selector 6: T1 timer

This selector sets the time length for the T1 timer.

Selectors 7 and 8: Elapsed time for time-out control

If the equipment receives no response (no G3 command) from the called terminal in automatic sending during the time set by these selectors, it disconnects the line.

V - 22

Page 115
Image 115
Brother FAX-931, MFC-970MC, FAX-921 service manual Station in automatic sending