1.DISASSEMBLY/REASSEMBLY

nSafety Precautions

To prevent the creation of secondary problems by mishandling, observe the following precautions during maintenance work.

(1)Unplug the power cord from the power outlet before replacing parts or units. When having access to the power supply, be sure to unplug the power cord from the power outlet.

(2)Be careful not to lose screws, washers, or other parts removed for parts replacement.

(3)When using soldering irons and other heat-generating tools, take care not to damage the resin parts such as wires, PCBs, and covers.

(4)Before handling the PCBs, touch a metal portion of the equipment to discharge static electricity; otherwise, the electronic parts may be damaged due to the electricity charged in your body.

(5)When transporting PCBs, be sure to wrap them in conductive sheets such as aluminum foil.

(6)Be sure to reinsert self-tapping screws correctly, if removed.

(7)Tighten screws to the torque values listed on the next page.

(8)When connecting or disconnecting cable connectors, hold the connector bodies not the cables. If the connector has a lock, always slide the connector lock to unlock it.

(9)Before reassembly, apply the specified lubricant to the specified points. (Refer to Section 2 in this chapter.)

(10)After repairs, check not only the repaired portion but also that the connectors and other related portions function properly before operation checks.