WSW27 (Function setting 5)
Selector | Function |
| Setting and Specifications | |||
No. |
| |||||
|
|
|
|
| ||
|
|
|
|
|
| |
1 | Definition of programmable key | 0: | TEL key | 1: | TEL/POLLING key | |
2 | Ringer OFF setting | 0: | Yes | 1: | No | |
|
|
|
|
|
| |
3 | Automatic playback of OGM at the | 0: | No | 1: | Yes | |
start time of OGM ON mode | ||||||
|
|
|
|
| ||
4 | Detection of distinctive ringing | 0: | Yes | 1: | No | |
pattern | ||||||
|
|
|
|
| ||
5 |
|
|
|
|
| |
Not used. |
|
|
|
| ||
8 |
|
|
|
|
| |
|
|
|
|
|
|
NOTE: Selector 1 is not applicable to the U.S.A. versions.
NOTE: Selector 3 is applicable to those models equipped with a
•Selector 1: Definition of programmable key
This selector defines a programmable key as a TEL key or TEL/POLLING key.
Setting this selector to "1" allows the programmable key to function as either a TEL or POLLING key if pressed when the handset is off or on the hook, respectively.
This setting is effective only for those models having a programmable key.
•Selector 2: Ringer OFF setting
This selector determines whether or not the ringer can be set to OFF.
•Selector 3: Automatic playback of OGM at the start time of OGM ON mode
This selector determines whether or not the equipment automatically plays back an OGM the moment it switches to the OGM ON mode in the MC mode.
•Selector 4: Detection of distinctive ringing pattern
If this selector is set to "1," the equipment detects only the number of rings; if it is set to "0," the equipment detects the number of rings and the ringing time length to compare the detected ringing pattern with the registered distinctive one.