WSW16 (Function setting 1)
Selector | Function | Setting and Specifications | ||
No. | ||||
|
|
| ||
|
|
|
| |
1 | Not used. |
|
| |
|
|
|
| |
2 | CCITT superfine recommendation | 0: OFF | 1: ON | |
|
|
|
| |
3 |
|
|
| |
Not used. |
|
| ||
6 |
|
|
| |
|
|
|
| |
7 | Max. document length limitation | 0: 400 cm | 1: 90 cm | |
|
|
|
| |
8 | Stop key pressed during reception | 0: Not functional | 1: Functional | |
|
|
|
|
•Selector 2: CCITT superfine recommendation
If this selector is set to "1," the equipment communicates in CCITT recommended superfine mode (15.4 lines/mm). If it is set to "0," it communicates in native superfine mode.
•Selector 7: Max. document length limitation
This selector is used to select the maximum length of a document to be sent.
•Selector 8: Stop key pressed during reception
If this selector is set to "1," pressing the Stop key can stop the current receiving operation. The received data will be lost.
V - 29