WSW31 (Function setting 9)

 

 

 

 

 

 

 

 

Selector

Function

 

Setting and Specifications

No.

 

 

 

 

 

 

 

 

 

 

 

 

1

Not used.

 

 

 

 

 

 

 

 

 

 

 

Default reduction rate for failure of

 

 

 

 

2

automatic reduction during

0:

100%

1:

50%

 

recording

 

 

 

 

3

Not used.

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Minimum short-OFF duration in

0:

130 ms

1:

90 ms

distinctive ringing

 

 

 

 

 

6

 

 

 

 

 

Not used.

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

NOTE: Selector 5 is applicable in those areas where the distinctive ringing is supported.

Selector 2: Default reduction rate for failure of automatic reduction during recording

This selector sets the default reduction rate to be applied if the automatic reduction function fails to record one-page data sent from the calling station in a single page of the current recording paper.

If it is set to “0,” the equipment records one-page data at full size (100%) without reduction; if it is set to “1,” the equipment records it at half size (50%).

Selector 5 Minimum short-OFF duration in distinctive ringing

The ringer pattern consists of short and long rings, e.g., short-short-long rings. This selector sets the minimum OFF duration following a short ring in order to avoid missing ringer tones in distinctive ringing.

If this selector is set to “1,” when the short-OFF duration is a minimum of 90 ms long, then the equipment will interpret the short-OFF as OFF.

V - 44

Page 137
Image 137
Brother FAX-921, MFC-970MC, FAX-931 service manual WSW31 Function setting