WSW06 (Pause key setting and 2nd dial tone detection)
Selector | Function |
|
| Setting and Specifications | ||
No. |
|
| ||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| No. 1 | 2 | 3 |
|
|
|
| 0 | 0 | 0 | : | No pause |
|
| 0 | 0 | 1 | : | 3.5 sec. WAIT |
1 |
| 0 | 1 | 0 | : | 7 sec. WAIT |
|
| 0 | 1 | 1 | : | 10.5 sec. WAIT |
Pause key setting and 2nd dial | 1 | 0 | 0 | : | 14 sec. WAIT | |
| tone detection | 1 | 1 | 0 | : | 2nd dial tone detection |
3 |
|
|
|
|
| only in pulse dialing (DP) |
|
|
|
|
| system | |
|
|
|
|
|
| |
|
| 1 | 0 | 1 | : | 2nd dial tone detection |
|
| 1 | 1 | 1 | : | both in DP and |
|
|
|
|
|
| (PB) dialing system |
|
| No. 4 | 5 | 6 |
|
|
|
| 0 | 0 | 0 | : | 50 ms |
4 |
| 0 | 0 | 1 | : | 210 ms |
|
| 0 | 1 | 0 | : | 500 ms |
Detection of international tone | 0 | 1 | 1 | : | 800 ms | |
|
| 1 | 0 | 0 | : | 900 ms |
6 |
| 1 | 0 | 1 | : | 1.5 sec. |
|
| 1 | 1 | 0 | : | 2.0 sec. |
|
| 1 | 1 | 1 | : | 2.5 sec. |
|
|
|
|
|
|
|
7 | No. of 2nd dial tone detection times | 0: Once |
| 1: Twice | ||
|
| |||||
|
|
|
|
|
|
|
8 | 2nd dial tone interrupt detecting | 0: | 30 ms |
| 1: 50 ms | |
time |
| |||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
NOTE: Selectors 4 through 8 are not applicable in those countries where no dial tone detection is supported, e.g., U.S.A.