Bryant manual BASE UNIT DIMENSIONS cont, 581B090-150

Models: 581B

1 64
Download 64 pages 44.36 Kb
Page 14
Image 14
BASE UNIT DIMENSIONS (cont)

BASE UNIT DIMENSIONS (cont)

UNIT

STANDARD

DURABLADE

ECONOMI$ER

CORNER

CORNER

CORNER

CORNER

“H”

 

“J”

 

“K”

 

“L”

 

UNIT WEIGHT

ECONOMIZER WEIGHT

WEIGHT

WEIGHT (A)

WEIGHT (B)

WEIGHT (C)

WEIGHT (D)

 

 

 

 

581B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

ft-in.

mm

ft-in.

 

mm

ft-in.

 

mm

ft-in.

mm

ft-in.

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

090

870

395

44

20

62

28.1

189

86

161

73

239

109

280

127

2-07/8

 

632

3-55/16

 

1050

2-911/16

856

2- 27/16

672

102

880

399

44

20

62

28.1

191

87

163

74

242

110

284

129

1-27/8

 

378

3-55/16

 

1050

2-911/16

856

2- 27/16

672

120

1035

469

44

20

62

28.1

225

102

192

87

285

129

333

151

1-27/8

 

378

4-15/16

 

1253

3-03/8

924

2-107/16

875

150

1050

476

44

20

62

28.1

228

103

195

88

289

131

338

153

1-27/8

 

378

4-15/16

 

1253

3-03/8

924

2-107/16

875

 

 

 

 

 

BOTTOM POWER CHART, THESE HOLES

 

 

 

CONNECTION SIZES

REQUIRED FOR USE WITH ACCESSORY PACKAGES —

A

13/8Dia [35]

Field Power Supply Hole

 

CRBTMPWR001A00, 2A00 (1/2, 3/4) OR

B

21/2Dia [64]

Power Supply Knockout

 

CRBTMPWR002A00, 4A00 (1/2, 11/4)

C

13/4Dia [44]

Charging-Port Hole

 

THREADED

WIRE

REQUIRED

 

D

7/8Dia [22] Field Control Wiring Hole

 

CONDUIT SIZE

USE

HOLE SIZES (MAX.)

 

E

3/4-14

NPT Condensate Drain

 

1/2

24 V

7/8[22.2]

 

 

1/2-14

NPT Gas Conn. — 581B090 & 102 —125 Heat

 

3/4

Power*

11/8[28.4]

 

F

3/4-14

NPT Gas Conn. — 581B090 to 120 — 180 Heat

 

 

 

 

 

 

11/4

Power*

13/4[44.4]

 

 

581B 090 to 150 — 224 Heat, 581B120 & 150 — 250 Heat

 

 

G

2Dia [51] Power Supply Knockout

 

(003) 1/2FPT

Gas

11/4[31.8]

 

 

 

 

 

 

(004) 3/4FPT

Gas

15/8[41.3]

 

*Select either 3/4or 11/4for power, depending on wire size.

NOTES:

1. Dimensions in [ ] are in millimeters.

2.581B090-150 Center of gravity.

3.Manual background Direction of airflow.

4.On vertical discharge units, ductwork to be attached to accessory roof curb only. For horizontal discharge units, field-supplied flanges should be attached to horizontal dis- charge openings, and all ductwork should be attached to the flanges.

5.Minimum clearance (local codes or jurisdiction may prevail):

a.Between unit, flue side and combustible surfaces, 48 inches.

b.Bottom of unit to combustible surfaces (when not using curb), 1 inch. Bottom of base rail to combustible surfaces (when not using curb) 0 inches.

c.Condenser coil, for proper airflow, 36 in. one side, 12 in. the other. The side getting the greater clearance is optional.

d.Overhead, 60 in. to assure proper condenser fan operation.

e.Between units, control box side, 42 in. per NEC (National Electrical Code).

f.Between unit and ungrounded surfaces, control box side, 36 in. per NEC.

g.Between unit and block or concrete walls and other grounded surfaces, control box side, 42 in. per NEC.

h.Horizontal supply and return end, 0 inches.

6.With the exception of the clearance for the condenser coil and combustion side as stated in notes 5a, b and c, a remov- able fence or barricade requires no clearance.

7.Units may be installed on combustible floors made from

wood or Class A, B, or C roof covering material if set on base rail.

8.The vertical center of gravity is 1-7[483] for 090 and 102, 1-11[584] for 120 and 150 up from the bottom of the base rail.

581B090-150

14

Page 14
Image 14
Bryant manual BASE UNIT DIMENSIONS cont, 581B090-150