Bryant manual PERFORMANCE DATA cont, 581B072 6 TONS — STANDARD MOTOR

Models: 581B

1 64
Download 64 pages 44.36 Kb
Page 36
Image 36
Manual background

PERFORMANCE DATA (cont)

FAN PERFORMANCE — HORIZONTAL DISCHARGE UNITS (cont)

581B072 (6 TONS) — STANDARD MOTOR

AIRFLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

 

 

 

 

 

0.2

 

 

 

0.4

 

 

 

0.6

 

 

0.8

 

1.0

 

 

 

1.2

 

 

 

 

1.4

 

1.6

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Rpm

 

Bhp

 

Rpm

 

 

Bhp

 

Rpm

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

 

Rpm

 

Bhp

 

Rpm

 

Bhp

 

Rpm

Bhp

 

1800

 

885

 

0.63

 

942

 

0.73

 

1047

 

0.90

 

1139

1.05

1193

 

1.14

1276

 

1.30

 

1341

 

1.40

 

1413

 

1.55

1474

1.58

 

1900

 

928

 

0.73

 

982

 

0.83

 

1084

 

1.02

 

1160

1.11

1223

 

1.24

1301

 

1.38

 

1374

 

1.53

 

1437

 

1.62

1490

1.67

 

2000

 

971

 

0.84

 

1022

 

0.94

 

1121

 

1.12

 

1188

1.22

1254

 

1.36

1329

 

1.44

 

1396

 

1.66

 

1460

 

1.68

1509

1.77

 

2100

 

1015

 

0.97

 

1063

 

1.10

 

1140

 

1.18

 

1196

1.27

1272

 

1.45

1354

 

1.58

 

1413

 

1.75

 

1475

 

1.73

1529

1.92

 

2200

 

1060

 

1.10

 

1104

 

1.20

 

1159

 

1.23

 

1229

1.41

1306

 

1.53

1363

 

1.70

 

1434

 

1.81

 

1487

 

1.85

1554

2.07

 

2300

 

1104

 

1.25

 

1130

 

1.27

 

1196

 

1.37

 

1264

1.56

1340

 

1.66

1397

 

1.86

 

1459

 

1.88

 

1520

 

2.07

1576

2.24

 

2400

 

1138

 

1.30

 

1174

 

1.37

 

1245

 

1.57

 

1305

1.63

1373

 

1.84

1440

 

1.95

 

1502

 

2.06

 

1552

 

2.24

 

 

 

 

1604

2.42

 

2500

 

1183

 

1.43

 

1201

 

1.50

 

1284

 

1.65

 

1338

1.75

1402

 

1.99

1469

 

2.04

 

1524

 

2.24

 

1585

 

2.42

1638

2.60

 

2600

 

1210

 

1.58

 

1243

 

1.67

 

1312

 

1.76

 

1366

1.96

1435

 

2.10

1494

 

2.19

 

1552

 

2.40

 

1616

 

2.63

1671

2.80

 

2700

 

1254

 

1.76

 

1285

 

1.80

 

1354

 

1.95

 

1403

2.14

1474

 

2.21

 

 

 

 

 

 

 

 

 

 

 

1646

 

2.83

1706

2.97

 

1536

 

2.46

 

1584

 

2.61

 

 

 

2800

 

1274

 

1.82

 

1304

 

1.85

 

1374

 

2.12

 

1459

2.25

1514

 

2.42

1570

 

2.66

 

1624

 

2.85

 

1677

 

2.99

 

 

2900

 

1318

 

1.95

 

1345

 

2.05

 

1412

 

2.32

 

1496

2.45

1529

 

2.61

1603

 

2.87

 

1671

 

3.03

 

 

 

 

 

3000

 

1362

 

2.20

 

1378

 

2.30

 

1451

 

2.40

 

1534

2.66

1560

 

2.81

1611

 

3.01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

581B072 (6 TONS) — HIGH-STATIC MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

 

0.6

 

 

0.8

1.0

 

1.2

 

1.4

 

 

 

 

 

 

1.6

 

 

1.8

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

 

Rpm

 

Bhp

 

Rpm

 

Bhp

 

Rpm

Bhp

Rpm

Bhp

 

Rpm

Bhp

Rpm

 

Bhp

 

Rpm

 

Bhp

 

Rpm

Bhp

 

Rpm

Bhp

 

1800

 

942

0.73

 

1047

 

0.90

 

1139

 

1.05

 

1193

1.14

1276

1.30

1341

1.40

1413

 

1.55

 

1474

 

1.58

 

1522

1.74

 

1566

1.89

 

1900

 

982

0.83

 

1084

 

1.02

 

1160

 

1.11

 

1223

1.24

1301

1.38

1374

1.53

1437

 

1.62

 

1490

 

1.67

 

1538

1.84

 

1583

2.00

 

2000

 

1022

0.94

 

1121

 

1.12

 

1188

 

1.22

 

1264

1.36

1329

1.44

1396

1.66

1460

 

1.68

 

1509

 

1.77

 

1558

1.95

 

1603

2.12

 

2100

 

1063

1.10

 

1140

 

1.18

 

1196

 

1.27

 

1272

1.45

1354

1.58

1413

1.75

1475

 

1.73

 

1529

 

1.92

 

1578

2.11

 

1624

2.30

 

2200

 

1104

1.20

 

1159

 

1.23

 

1229

 

1.41

 

1306

1.53

1363

1.70

1434

1.81

1487

 

1.85

 

1554

 

2.07

 

1604

2.28

 

1651

2.48

 

2300

 

1130

1.27

 

1196

 

1.37

 

1264

 

1.56

 

1340

1.66

1397

1.86

1459

1.88

1520

 

2.07

 

1576

 

2.24

 

1627

2.46

 

1674

2.68

 

2400

 

1174

1.37

 

1245

 

1.57

 

1305

 

1.63

 

1373

1.84

1440

1.95

1502

2.06

1552

 

2.24

 

1604

 

2.42

 

1656

2.66

 

1704

2.90

 

2500

 

1201

1.50

 

1284

 

1.65

 

1338

 

1.75

 

1402

1.99

1469

2.04

1524

2.24

1585

 

2.42

 

1638

 

2.60

 

1691

2.86

 

1740

3.12

 

2600

 

1246

1.67

 

1312

 

1.76

 

1366

 

1.96

 

1435

2.10

1494

2.19

1552

2.40

1616

 

2.63

 

1671

 

2.80

 

1726

3.09

 

1775

3.35

 

2700

 

1285

1.80

 

1354

 

1.95

 

1403

 

2.14

 

1474

2.21

1536

2.46

1584

2.61

1646

 

2.83

 

1706

 

2.97

 

1761

3.27

 

 

2800

 

1304

1.85

 

1374

 

2.12

 

1459

 

2.25

 

1514

2.42

1570

2.66

1624

2.85

1677

 

2.99

 

1739

 

3.33

 

1795

3.67

 

 

2900

 

1345

2.05

 

1412

 

2.32

 

1496

 

2.54

 

1529

2.61

1603

2.87

1671

3.03

1742

 

3.43

 

 

 

 

 

 

3000

 

1378

2.30

 

1451

 

2.40

 

1534

 

2.66

 

1560

2.81

 

 

1692

3.49

1764

 

3.95

 

 

 

 

 

 

1611

3.01

 

 

 

 

 

 

LEGEND

Bhp — Brake Horsepower Input to Fan

FIOP — Factory-Installed Option

NOTES:

1.Boldface indicates field-supplied drive required. (See Note 3.)

2.Manual backgroundManual background indicates field-supplied motor and drive required.

3.Motor drive range is 1120 to 1585 rpm for standard motors; 1300 to 1685 rpm for high-static motors. All other rpms require a field-supplied drive.

4.Values include losses for filters, unit casing, and wet coils. See page 40 for accessory/FIOP static pressure information.

5.Maximum continuous bhp is 2.4 for standard motors; 2.9 for high-static motors. Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with confidence. Using your fan motors up to the ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. See Evaporator-Fan Motor Data tables on pages 41 and 42 for additional information.

6.Use of a field-supplied motor may affect wire sizing. Contact your Bryant rep- resentative to verify.

7.Interpolation is permissible. Do not extrapolate.

36

Page 36
Image 36
Bryant manual PERFORMANCE DATA cont, 581B072 6 TONS — STANDARD MOTOR