Cabletron Systems 1088 MAC Address, MAC Count, Non Master Ports, FDDI Ring Stats, Ring State

Models: 1082 1088 SM-CSI1076

1 69
Download 69 pages 59.11 Kb
Page 49
Image 49

C o n f i g u r a t i o n V i e w s

F d d i M A C D e v i c e C o n f i g u r a t i o n V i e w

MAC Address

The MAC (physical) address of this station.

MAC Count

The number of MACs supported by this station.

Non Master Ports

The number of non-master ports on this station.

Master Ports

The number of master ports on this station.

 

Table 20: FDDI Ring Stats

 

 

Ring State

Description

 

 

Isolated

The concentrator is not attached to the ring.

 

 

Non-Op

The concentrator is attempting to enter the ring.

 

 

Ring-Op

The ring is operational.

 

 

Detect

The claim/beacon process of the FDDI ring protocol has exceeded one second. This indicates a potential

 

problem.

 

 

Non-Op-Dup

The ring failed to complete the claim/beacon process because a duplicate FDDI address has been

 

detected.

 

 

Ring-Op-Dup

The ring is operational, but a duplicate FDDI address has been detected.

 

 

Directed

The claim/beacon process did not complete within nine seconds. The concentrator is now sending

 

directed beacons to indicate a problem.

 

 

Trace

A problem has been detected with the station or its upstream neighbor. A trace is being sent to notify the

 

upstream neighbor of the problem. The concentrator and all stations between the concentrator and its

 

upstream neighbor can perform self-tests.

 

 

S p e c t r u m E n t e r p r i s e M a n a g e r

Page 50

S m a r t S w i t c h 6 0 0 0

Page 49
Image 49
Cabletron Systems 1088, 1082 manual MAC Address, MAC Count, Non Master Ports, FDDI Ring Stats, Ring State, Description, Page