Recording Video

Using the Internal Cooling Fan

During

mode, the camera uses an internal cooling fan that is always on by default to reduce the camera’s

internal heat. Alternatively, you can set the cooling fan to activate when the camcorder’s internal temperature

reaches a predetermined level.

 

61

 

 

 

 

 

Operating modes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Open the [Fan] submenu.

 

 

 

 

 

[wOther Functions]

[wOther Functions] >[Fan]

 

 

 

 

 

2 Select the desired option and then press SET.

[Fan]

Options

 

 

 

 

 

 

 

[On]:

The cooling fan is active at all times regardless of the camera’s

[On]

 

internal temperature.

 

 

 

 

 

 

 

 

 

[Automatic]:

When the camcorder’s internal temperature is below a predetermined

 

 

 

 

level, the cooling fan will not activate. When the internal temperature

 

 

 

 

reaches the predetermined level, a message will appear and the cooling

 

 

 

 

fan will activate automatically (

will appear on the screen).

 

 

 

NOTES

During 4K and 2K modes, when the cooling fan is set to [Automatic] and the camera has cooled down, the cooling fan will activate in approximately 10 minutes, based on a surrounding temperature of 25 °C (77 °F). Also, depending on the surrounding temperature, the cooling fan may stop after a short period of time or continue to operate.