Recording Video
Using the Internal Cooling Fan
During | mode, the camera uses an internal cooling fan that is always on by default to reduce the camera’s | ||||||
internal heat. Alternatively, you can set the cooling fan to activate when the camcorder’s internal temperature | |||||||
reaches a predetermined level. |
| 61 | |||||
|
|
|
|
| |||
Operating modes: |
|
|
|
|
|
| |
|
|
|
|
|
| ||
|
|
|
|
| |||
1 Open the [Fan] submenu. |
|
|
|
| |||
| [wOther Functions] | ||||||
[wOther Functions] >[Fan] |
| ||||||
|
|
|
| ||||
2 Select the desired option and then press SET. | [Fan] | ||||||
Options |
|
|
|
|
|
|
|
[On]: | The cooling fan is active at all times regardless of the camera’s | [On] | |||||
| internal temperature. |
|
|
|
| ||
|
|
|
|
| |||
[Automatic]: | When the camcorder’s internal temperature is below a predetermined |
|
|
| |||
| level, the cooling fan will not activate. When the internal temperature |
|
|
| |||
| reaches the predetermined level, a message will appear and the cooling |
|
|
| |||
| fan will activate automatically ( | will appear on the screen). |
|
|
|
NOTES
•During 4K and 2K modes, when the cooling fan is set to [Automatic] and the camera has cooled down, the cooling fan will activate in approximately 10 minutes, based on a surrounding temperature of 25 °C (77 °F). Also, depending on the surrounding temperature, the cooling fan may stop after a short period of time or continue to operate.