Carrier 50FK, JK034-074, 48FK specifications Legend And Notes For Fig

Models: 48FK 50FK JK034-074

1 60
Download 60 pages 6.49 Kb
Page 55
Image 55
LEGEND AND NOTES FOR FIG. 55

LEGEND AND NOTES FOR FIG. 55

ALM

Ð Alarm

LAT

Ð Leaving-Air Temperature

C

Ð Contactor

LPS

Ð Low-Pressure Switch

CB

Ð Circuit Breaker

MTR

Ð Motor

CCB

Ð Control Circuit Breaker

MV

Ð Main Valve

COMP

Ð Compressor

NC

Ð Normally Closed

CH

Ð Crankcase Heater

NO

Ð Normally Open

CR

Ð Control Relay

OFC

Ð Outdoor Fan Contactor

DPS

Ð Differential Pressure Switch

OFM

Ð Outdoor (Condenser) Fan Motor

DPT

Ð Discharge Pressure Transducer

OMR

Ð Outdoor Motor Relay

EAT

Ð Enering-Air Temperature

PCB

Ð Power Exhaust Circuit Breaker

EC

Ð Enthalpy Control

PEC

Ð Power Exhaust Contactor

ECR

Ð Economizer Close Relay

PEDM Ð Power Exhaust Damper Motor

EOR

Ð Economizer Open Relay

PEM

Ð Power Exhaust Motor

EQUIP

Ð Equipment

P, PL

Ð Plug

FS

Ð Fan Status Switch

RCB

Ð Return Fan Circuit Breaker

GND

Ð Ground

RES

Ð Resistor

HIR

Ð Heat Interlock Relay

RFC

Ð Return Fan Contactror

HPS

Ð High-Pressure Switch

RFM

Ð Return Fan Motor

HR

Ð Heater Relay

SCT

Ð Saturated Condensing Thermistor

HTR

Ð Heater

TB

Ð Terminal Block

IDC

Ð Induced Draft Contactor

TRAN

Ð Transformer

IDM

Ð Induced Draft Motor

U

Ð Unloader

IFC

Ð Indoor (Evaporator) Fan Contactor

VFD

Ð Variable Frequence Drive

IFCB

Ð Indoor Fan Circuit Breaker

 

Field Wiring

IGV

Ð Inlet Guide Vanes

 

 

Factory Wiring

IGVM

Ð Inlet Guide Vanes Motor

 

NOTES:

1. Connect TRAN1 to H4 for 460 v units. Connect to H3 for 230 v units. If 208/230 v units are run with a 208 v power supply connect to H2 .

2.Connect TRAN2 to BLK lead for 460 v units. Connect to ORN lead for 230 v units. If 208/230 v units are run with a 208 v power sup- ply connect to RED lead.

3.Circuit breaker must trip amps are equal to or less than 156% FLA (full load amps) for CB1 and CB2. All others are 140%.

4.If any of the original wire furnished must be replaced, it must be replaced with type 90° C wire or its equivalent.

5.Number(s) indicates the line location of contacts. A bracket over

(2) numbers signi®es single pole double throw contacts. An un- derlined number signi®es a normally closed contact. Plain num- bers (no lines), signify a normally opened contact.

6.Condenser fan motors are thermally protected.

7.Three phase motors are protected under primary single phasing conditions.

55