WATER CONNECTIONS

 

ELECTRICAL KNOCKOUTS (in.)

DISCHARGE CONNECTION

RETURN CONNECTION

 

 

OVERALL CABINET

 

1

2

 

 

3

 

 

J

K

L

Duct Flange Installed (±0.10 in.)

Using Air Coil Opening

50RVC

 

 

 

 

 

 

 

 

Water

1/2 conduit

1/2 conduit

3/4 conduit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNITS

 

A

B

C

D

 

E

F

G

H

 

I

FPT

 

Ext.

Power

 

 

O

P

 

 

S

T

 

 

 

 

 

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Therm

M

N

Supply

Supply

Q

R

Return

Return

U

 

 

Width

Depth

Height

 

In

Out

Condensate

 

Pump

Supply

 

 

 

 

 

 

 

Width

Depth

 

 

Depth

Height

 

009-012

in.

19.1

19.1

22.0

1.4

 

2.8

9.4

2.8

6.1

 

2.3

1/2

2.9

5.9

8.9

8.9

5.1

9.0

9.0

5.5

2.1

16.2

9.9

0.7

cm

48.5

48.5

55.9

3.6

 

7.1

24.0

7.1

15.6

 

5.9

1.3

7.3

14.9

22.5

22.7

12.9

22.9

22.9

14.0

5.3

41.1

25.1

1.9

 

 

 

018-030

in.

21.5

21.5

39.0

1.8

 

3.8

15.2

3.6

8.1

 

2.3

3/4

4.1

7.1

10.1

6.4

3.8

14.0

14.0

5.3

2.3

18.3

20.2

0.7

cm

54.6

54.6

99.1

4.5

 

9.7

38.6

9.1

20.6

 

5.8

1.9

10.5

18.1

25.7

16.1

9.5

35.6

35.6

13.6

5.8

46.5

51.3

1.9

 

 

 

036 & 042

in.

21.5

26.0

44.0

2.0

 

3.7

16.2

2.6

10.4

 

2.3

3/4

4.1

7.1

10.1

6.4

3.8

14.0

14.0

5.1

2.3

22.8

24.2

0.7

 

cm

54.6

66.0

111.8

5.1

 

9.4

41.1

6.6

28.4

 

5.8

1.9

10.5

18.1

25.7

16.1

9.5

35.6

35.6

13.1

5.8

57.9

61.4

1.9

041

in.

21.5

21.5

39.0

1.7

 

3.6

16.4

2.6

8.1

 

2.3

3/4

4.1

7.1

10.1

6.4

3.8

14.0

14.0

5.3

2.3

18.3

20.2

0.7

cm

54.6

54.6

99.1

4.4

 

9.1

41.7

6.6

20.6

 

5.8

1.9

10.5

18.1

25.7

16.1

9.5

35.6

35.6

13.6

5.8

46.5

51.3

1.9

 

 

 

048-060

in.

24.0

32.5

46.0

1.8

 

5.9

16.7

2.3

10.1

 

2.3

1

4.1

7.1

10.1

6.9

7.3

16.0

18.0

5.1

2.3

29.3

24.2

0.7

cm

6.10

82.6

116.8

4.5

 

14.9

42.4

5.8

25.7

 

5.8

2.5

10.5

18.1

25.7

17.4

18.4

40.6

45.7

13.1

5.8

74.4

61.4

1.9

 

 

 

NOTES:

1.Condensate is 3/4-in. (19.1 mm) FPT.

2.Filter bracket extending from unit 2.5-in. (6.4 cm). This bracket should be removed when connecting return duct.

3.Discharge flange field installed.

LEGEND

ASP — Alternate Service Panel

BSP — Blower Service Panel

CAP — Control Access Panel

CSP — Compressor Service Panel

AIRFLOW CONFIGURATION

Code

Return

Discharge

L

Left

Top

R

Right

Top

Fig. 5 — 50RVC Dimensional Data

10

Page 10
Image 10
Carrier RHR, RVS, RDS006-060, RVR, RVC, RHS, 50RHC specifications Right Top