Carrier RVC, RVS, RDS006-060, RHR, RHS, 50RHC specifications 50RVR Dimensional Data

Models: 50RHC RHS RVC RHR RVR RDS006-060 RVS

1 44
Download 44 pages 51.02 Kb
Page 11
Image 11
Fig. 6 — 50RVR Dimensional Data

 

 

 

 

 

WATER CONNECTIONS

ELECTRICAL KNOCKOUTS (in.)

DISCHARGE CONNECTION

RETURN CONNECTION

50RVR

 

OVERALL CABINET

1

2

3

Loop

G

H

I

Duct Flange Installed (±0.10 in.)

Using Air Coil Opening

 

 

 

 

1/2 conduit

1/2 conduit

3/4 conduit

 

 

 

 

 

 

 

 

 

UNITS

 

 

 

 

 

 

 

Water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

C

D

E

F

FPT

 

 

Power

 

 

L

M

 

 

P

Q

 

 

 

Cond-

(in.)

Therm

Ext Pump

J

K

Supply

Supply

N

O

Return

Return

R

 

 

Width

Depth

Height

In

Out

Supply

 

 

ensate

 

 

 

 

 

Height

Depth

 

 

Depth

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

009-012

in.

22.4

21.6

22.6

2.6

5.4

7.8

1/2

3.5

5.5

8.2

10.6

6.8

5.8

8.0

6.0

2.2

17.1

9.3

1.0

cm

56.8

54.9

57.4

6.6

13.7

19.8

8.9

14.0

20.8

26.9

17.3

14.7

20.3

15.2

5.6

43.4

23.6

2.5

 

 

015-024

in.

22.4

21.6

34.6

2.4

4.8

8.5

3/4

3.5

7.5

10.2

7.2

3.8

14.0

14.0

4.3

2.2

17.1

15.3

1.0

cm

56.8

54.9

87.9

6.1

12.2

21.6

8.9

19.1

25.9

18.3

9.7

35.6

35.6

10.9

5.6

43.4

38.9

2.5

 

 

030

in.

22.4

25.6

40.6

2.4

5.4

9.7

3/4

5.7

9.7

12.2

7.2

5.8

14.0

14.0

4.3

2.2

21.1

19.2

1.0

cm

56.8

65.1

103.1

6.1

13.7

24.6

14.5

24.6

31.0

18.3

14.7

35.6

35.6

10.9

5.6

53.6

48.8

2.5

 

 

036

in.

22.4

25.6

40.6

2.4

5.4

9.7

3/4

5.7

9.7

12.2

7.2

5.8

14.0

14.0

4.3

2.2

21.1

19.2

1.0

cm

56.8

65.1

103.1

6.1

13.7

24.6

14.5

24.6

31.0

18.3

14.7

35.6

35.6

10.9

5.6

53.6

48.8

2.5

 

 

042-048

in.

22.4

25.6

48.6

2.4

5.4

9.7

1

5.7

9.7

12.2

7.2

5.8

14.0

14.0

4.3

2.2

21.1

27.2

1.0

cm

56.8

65.1

123.4

6.1

13.7

24.6

14.5

24.6

31.0

18.3

14.7

35.6

35.6

10.9

5.6

53.6

69.1

2.5

 

 

060

in.

25.4

30.6

50.6

2.4

5.4

10.7

1

8.1

11.7

14.2

6.2

6.3

18.0

18.0

5.1

2.2

26.1

27.2

1.0

cm

64.5

77.8

128.5

6.1

13.7

27.2

20.6

29.7

36.1

15.7

16.0

45.7

45.7

13.0

5.6

66.3

69.1

2.5

 

 

NOTES:

1.Condensate is 3/4-in. FPT and is switchable from side to front.

2.Vertical unit shipped with filter bracket only extending from unit 2.5 inches. This bracket should be removed when connecting return duct.

3.Discharge flange field installed.

4.Right and left orientation is determined by looking at water connection side.

 

 

 

 

 

 

 

Field Installed

 

 

 

 

 

 

 

Discharge Flange

 

 

 

 

LEGEND

 

 

(Shipped loose in

 

 

 

 

 

 

blower section)

 

 

 

ASP — Alternate Service Panel

 

Standard Filter Bracket

 

 

 

 

 

 

 

 

BSP — Blower Service Panel

 

 

 

 

 

 

CAP — Control Access Panel

 

 

 

 

 

 

CSP — Compressor Service Panel

 

 

RIGHT RETURN

 

 

LEFT RETURN

 

 

Air Coil

 

 

 

 

 

 

 

 

M

K

 

B

 

 

BSP

 

K

M

 

 

 

 

 

 

 

 

L

Front

 

 

Front

L

 

 

 

 

 

 

 

 

 

 

 

A

CSP

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP

Water Connection

Access Panels

ASP

3Service

Access

Left Return

ASP(right

Opposite)

N

Air Coil Side

 

 

Air Coil Side

J

 

 

 

 

 

 

 

R Configuration - Top View-Right Return

L Configuration - Top View-Left Return

Front

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water

 

P

 

O

P

 

3Service

 

 

Isometric

 

Connections

 

O

 

 

 

 

 

 

 

Access

 

 

View

 

 

 

R

 

 

R

 

 

 

 

 

 

 

1.000

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Coil

 

Air Coil

 

 

 

 

 

 

 

Q

 

 

Q

 

 

 

 

 

 

 

 

 

C

 

 

C

 

 

 

 

 

 

 

 

Condensate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply

 

 

 

 

 

3/4FPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4HV Knockout

 

 

 

 

 

 

 

 

 

 

 

 

Power for

 

 

CAP

 

 

 

 

 

 

 

 

 

Condensate Pump

 

 

 

 

 

 

 

 

 

 

 

 

1/2Knockout

 

 

 

 

 

 

 

ASP

 

 

CSP

 

Low Voltage

 

 

I

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2LV Knockout

 

H

 

 

 

Front

 

Back

Back

 

Front

CSP

G

 

2

 

F

 

 

 

 

1

 

E

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

R Configuration - Right Return Right View

L Configuration - Left Return Left View

 

 

Front View

 

 

 

 

- Air Coil Opening

 

 

- Air Coil Opening

 

 

 

 

 

 

 

 

 

AIRFLOW CONFIGURATION

 

 

 

 

 

 

 

 

 

 

Code

Return

Discharge

 

 

 

 

 

 

 

 

 

L

Left

 

Top

 

 

 

 

 

 

 

 

 

R

Right

 

Top

 

 

 

 

 

 

 

 

 

Fig. 6 — 50RVR Dimensional Data

11

Page 11
Image 11
Carrier RVC, RVS, RDS006-060, RHR, RHS, 50RHC specifications 50RVR Dimensional Data