ε-4

Using the Setup Wizard

9.If there is no problem with the contents of the confirmation screen, press 1.

If you need to change the setup, press 6 or J. This will return to the screen in step 4 (for setting the total sampling interval), where you can change the setting.

Pressing 1 will take you to the final Setup Wizard screen.

10. Press number keys described below to specify what you want to do with the setup you have configured.

b(Start Setup)................

Starts sampling using the setup (page ε-30)

c(Save Setup-MEM) .....

Saves the setup (page ε-24)

d(Convert Program) ......

Converts the setup to a program (page ε-27)

kUsing Setup Wizard to Configure Settings for FFT (FrequencyCharacteristics) Data Sampling

When you perform sound sampling executed by the EA-200’s built-in microphone (by specifying [CASIO] - [Microphone] as the sensor), Setup Wizard will provide you with three options: [Sound wave], [Sound wave & FFT], and [FFT only]. “Sound wave” records the following two dimensions for the sampled sound data: elapsed time (horizontal axis) and volume (vertical axis). “FFT” records the following two dimensions: frequency (horizontal axis) and volume (vertical axis).

The following shows the settings for recording FFT data.

1.Perform the first two steps of the procedure under “To configure an EA-200 setup using Setup Wizard” on page ε-2.

2.On the “Select Sensor” screen, select [CASIO] - [Microphone] - [Sound wave & FFT] or [CASIO] - [Microphone] - [FFT only].

This causes a “Select FFT Range” screen to appear.

You can select one of four settings for FFT Range. The setting you select will automatically apply the applicable fixed parameters shown below.

Setting

 

2 - 1000 Hz:

4 - 2000 Hz:

6 - 3000 Hz:

8 - 4000 Hz:

Parameter

 

1

2

3

4

 

 

 

 

 

Frequency pitch

 

2 Hz

4 Hz

6 Hz

8 Hz

 

 

 

 

 

 

Upper limit of sampling frequency

 

1000 Hz

2000 Hz

3000 Hz

4000 Hz

Sampling interval

 

61 μsec

31 μsec

20 μsec

31 μsec

 

 

 

 

 

 

Number of samples

 

8192

8192

8192

4096

 

 

 

 

 

 

3.Use function keys 1 through 4 to select an FFT Range setting.

• Selecting an FFT Range causes the final Setup Wizard screen to appear.

4.Perform step 10 under “To configure an EA-200 setup using Setup Wizard” on page ε-2 to finalize the procedure.