A-27
Cisco ONS 15454 Reference Manual, R8.5.x
78-18106-01
Appendix A Hardware Specifications
A.5.10 FILLER Card Specifications
C-Temp (15454-DS3XM-6): 0 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)
I-Temp (15454-DS3XM-6-T): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius)
Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card
without this symbol is C-Temp compliant.
Operating humidity: 5 to 95 percent, noncondensing
Power consumption: 20 W, 0.42 A, 68 BTU/hr
Dimensions
Height: 12.650 in. (321.3 mm)
Width: 0.716 in. (18.2 mm)
Depth: 9.000 in. (228.6 mm)
Card weight: 1.8 lb (0.8 kg)

A.5.10 FILLER Card Specifications

The FILLER cards have the following specifications:
Environmental
Operating temperature:
C-Temp: -40 to +149 degree Fahrenheit (-40 to +65 degrees Celsius)
Operating humidity: 5 to 95 percent, noncondensing
Dimensions
Height: 12.650 in. (321.3 mm)
Width: 0.716 in. (18.2 mm)
Depth: 9.000 in. (228.6 mm)
Card weight: 0.4 lb (0.19 kg)
A.6 Optical Card Specifications
This section provides specifications for the OC3 IR4/STM1 SH 1310 (four-port), OC3 IR/STM1 SH
1310-8 (eight-port), OC12 IR/STM4 SH 1310, OC12 LR/STM4 LH 1310, OC12 LR STM4 LH 1550,
OC12 IR/STM4 SH 1310-4 (four-port), OC48 IR 1310, OC48 LR 1550, OC48 IR/STM16 SH AS 1310 ,
OC48 LR/STM16 LH AS 1550, OC48 ELR 100 GHz, OC48 ELR 200 GHz, OC192 SR/STM64 IO 1310,
OC192 IR/STM64 SH 1550, OC192 LR/STM64 LH 1550, OC192 L R/STM64 LH ITU 15xx.xx,
15454_MRC-12 (12-port), MRC-2.5G-4, OC192SR1/STM64IO Short Reach, and O C192/STM64 Any
Reach cards.
For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance
Information.